Temperature Range: 32º - 112ºF
Input Voltage: 115 or 230 VAC,
single phase, 60Hz
Output Current: 10 Amps maximum, per
stage
Alarm Relay Output for high or low
temperature or loss of power
Individual stage indicator LEDs
Low temperature Auto-Off control of
vent mode stages Up to 3 temperature
Sensors may be connected. A temperature sensor may be extended
up to a length of 250 feet using a sensor extension kit and sensor
extension cable
Individually adjustable set points for
each stage relative to the control set point temperature
Field adjustable choice of either
(A) low-speed continuous fan operation below Set-point Temperature or
(B) fan shut-off below Set-point Temperature on Variable Speed cooling
stages
Built in serial communications port allows
multiple controls to be networked together with a PC for remote
observation and adjustment with e-VENT software
Click
Here for current e-VENT control models. Call Customer Service
about control customization options if an existing control does not meet
your needs. |