Power-Up™
is an AV-11 feature that cold-starts motors at full speed, then
reverts to preset speed. This means full fan horsepower overcomes
fan and shutter inertia and avoids fan start-up stalling or cold weather
freeze-up. Power-up protects fan motors and safeguards Agri-Aide
ventilation systems.
Control many fans. Note: control only fans of the same
horse-power. Overload fuse (Part KE-AV1102) protection built in.
Watertight enclosure protects control circuitry from the
inside environment. Built-in radio frequency, transient and
voltage surge arrestors protect control from all but direct lightning.
Field adjustable choice of either (A) low-speed continuous fan
operation below Set-point Temperature or (B) fan shut-off below
Set-point Temperature. Use (A) when controlling minimum winter
exhaust fan; use (B) when another fan supplies minimum winter exhaust.
Input Voltage: 120 or 240 VAC
Output Voltage: 11 Amp Capacity
Minimum Speed Adjustment Range: 20% to 100% of fan full power
Temperature Range: 35º - 95ºF |